BPZRX - NICKEL CADMIUM STORAGE BATTERY P/N 19535

Product Identification

Product ID:NICKEL CADMIUM STORAGE BATTERY P/N 19535
MSDS Date:03/05/1991
FSC:6140
NIIN:00-449-9839
MSDS Number: BPZRX

Responsible Party
SAFT AMERICA INC POWER SOURCES DIV
711 INDUSTRIAL BLVD
VALDOSTA, GA 31603
US

Emergency Phone: 912-247-2331

Info Phone: 912-247-2331

Preparer: BETH LAS

Cage: 09052

Contractor
SAFT AMERICA INC.
1886 VALDOSTA, GA 31602 US

Telephone: 912-247-2331

Cage: 09052

Ingredients

CADMIUM (SARA III) AND CADMIUM HYDROXIDE

CAS: 7440-43-9

RTECS: EU9800000

Fraction By Weight: 7-13%

OSHA PEL SEE 1910.1027

ACGIH TLV: 0.01 MG/M3 DUST;9394

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


NICKEL (SARA III) AND NICKEL HYDROXIDE

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 23-30%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9293


POTASSIUM HYDROXIDE (SARA III)

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 4 - 8%

OSHA PEL C, 2 MG/M3

ACGIH TLV: C 2 MG/M3; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


COBALT HYDROXIDE

CAS: 21041-93-0

Fraction By Weight: 0.5%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:UNDER NORMAL CONDITIONS OF USE, NO
EXPOSURE TO HAZARDOUS COMPONENTS EXISTS. IF INCINERATED, INHALATION
OF FUMES MAY CAUSE RESPIRATORY SYSTEM IRRITATION TO PULMONARY
EDEMA; CHRONIC EXPOSURE MAY CAUSE K IDNEY DYSFUNCTION AND LUNG
INJURY.
Explanation of Carcinogenicity:CONTAINS NICKEL WHICH IS LISTED AS
CARCINOGENIC AND CADMIUM AS POSSIBLY CARCINOGENIC.
Effects of Overexposure:IF INCINERATED, CHEST PAINS, COUGHING, SWEATING
CHILLS, SHORTNESS OF BREATH AND WEAKNESS.
Medical Cond Aggravated by Exposure:IF INCINERATED, RESPIRATORY SYSTEM
DISORDERS, PROSTATE DISORDERS, LIVER AND KIDNEY DISORDERS.

First Aid

First Aid:GET MEDICAL ATTENTION IF SYMPTOMS PERSIST.
EYE/SKIN:IMMEDIATELY FLUSH WITH WATER FOR AT LEAST 15 MINUTES,IF
CONTACTED WITH ELECTROLYTES.HOLD EYELIDS OPEN.INHALED:REMOVE TO
FRESH AIR.ORAL:CALL A PHYSIC IAN IMMEDIATELY.

Fire Fighting

Extinguishing Media:SUITABLE FOR SURROUNDING MATERIAL.
Fire Fighting Procedures:USE NIOSH-APPROVED SELF CONTAINED BREATHING
APPARATUS AND FULL PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:TOXIC METAL OXIDE FUMES MAY BE EVOLVED
DURING BURNING.

Accidental Release

Spill Release Procedures:UNDER NORMAL CONDITIONS OF USE, HAZARDOUS
COMPONENTS WILL NOT BE RELEASED. IF ELECTROLYTE IS SPILLED,
NEUTRALIZE WITH MILD ACID THEN FLUSH WITH WATER.
Neutralizing Agent:WEAK ACID

Handling

Handling and Storage Precautions:DO NOT BREAK OPEN BATTERY CASE. DO NOT
INCINERATE OR MUTILATE. DO NOT SHORT CIRCUIT, MAY CAUSE BURNS.
Other Precautions:IF CASE IS BROKEN OPEN, ELECTROLYTE IS CORROSIVE ON
CONTACT. IMPERVIOUS GLOVES, SAFETY GOGGLES AND OTHER PROTECTIVE
CLOTHING AND EQUIPMENT SHOULD BE WORN IN THE UNLIKELY EVENT OF
CONTACT.

Exposure Controls

Respiratory Protection:WEAR NIOSH/MSHA APPROVED SELF-CONTAINED
BREATHING APPARATUS TO PROTECT AGAINST FUMES.
Ventilation:NORMAL VENTILATION.
Protective Gloves:IF PUNCTURED CASE, USE IMPERVIOUS GLOVES
Eye Protection:IF PUNCTURED CASE, WEAR SAFETY GOGGLES
Other Protective Equipment:IF INVOLVED IN A FIRE, FULL PROTECTIVE
CLOTHING.
Work Hygienic Practices:AVOID CONTACT WITH INNER COMPONENTS.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:B1
Appearance and Odor:OUTER METAL CASING CONTAINING PRISMATIC CELLS WITH
COMPONENTS SEALED WITHIN.

Stability

Stability Indicator/Materials to Avoid:YES
GENERAL STORAGE PROCEDURES FOR HAZARDOUS MATERIALS ARE ACCEPTABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:METAL OXIDES FUMES MAY BE EVOLVED AT
TEMPERATURES ABOVE MELTING POINT.

Disposal

Waste Disposal Methods:IF DISCARDED, TREAT AS RCRA HAZARDOUS WASTE.
DISPOSE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL LAWS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.